Call-centre acoustic treatment is a critical intervention so agents can communicate clearly with customers, are not affected by neighbouring stations and have a low fatigue level by end of shift in heavy-conversation environments. Acoustic ceiling + tall dividers + sound masking + headset-friendly design combination is used.
Why is call-centre acoustics different?
A call centre, unlike a standard office, has agents talking 100% of their working time. The acoustic requirements exceed a standard office:
- The agent hearing the customer clearly (STI 0.65+)
- Speech from the next station minimum (Privacy Index 0.80+)
- Low room reverberation (RT60 0.4-0.5 s)
- Reducing constant-speech fatigue
Solution components
- Acoustic ceiling: high-NRC (≥ 0.90) panel
- Tall desk divider (1.5-1.7 m): blocks sound to neighbouring stations
- Wall absorber panels: side and rear wall covering
- Sound masking: pink noise for privacy
- Acoustic carpet: floor reflections reduced
- Break-area separation: high-divider rest area
Sound masking — a critical element
Sound masking is a standard requirement in call centres. In our practice, agent fatigue and error rates are reported 20-30% higher in spaces designed without sound masking. Correctly tuned pink noise creates the feeling of privacy without staff even noticing it.
Target performance
- RT60: 0.4-0.5 s
- STI at agent: 0.65+
- Privacy Index: 0.80+
- NC: 35-40
- Sound masking: tuned to specific agent environment
Productivity and health
In acoustically comfortable call centres:
- Agent productivity rises 15-25%
- Customer satisfaction rises (clear communication)
- Worker fatigue drops, absenteeism falls
- Error rate drops 20%+
Lead time and cost
A typical mid-sized call centre 2-3 weeks. Break periods are used so agent workflow is not disrupted. Investment varies with worker count, space size and the sound-masking system.
Certificates
EN 13501-1 fire-class materials, EN ISO 354 NRC-certified acoustic panels and ceiling products.
Features
On-site acoustic measurement and noise source analysis
Detailed engineering with professional simulation software
Certified material selection (BS476 Class 0, UNI 9175)
Meticulous installation and execution with our experienced team
Final measurement and performance warranty report
Process
Survey & Measurement
On-site survey and acoustic measurement.
Simulation & Design
Simulation with acoustic software, detailed quote.
Installation
Turnkey installation with certified materials.
Verification & Report
Final measurement, performance report, warranty.
Technical Specifications
| Application Standard | BS476 Class 0, UNI 9175 M1, Firex |
|---|---|
| Typical Noise Reduction | 25-45 dB (project-dependent) |
| Installation Time | Confirmed after survey (1-15 days) |
| Warranty | Measured result + 2-year workmanship warranty |